A restart that has to be signed off needs a switch that will not do it by itself. This latches when the rope is pulled: the NC contact opens, the drive stops, and both contacts stay where they are after the rope is released. Closing the circuit again takes a person at the unit and a press of the blue reset button on the housing. Where the restart is part of a written procedure rather than an accident of the rope, that is the behaviour a has to have.
- : The NC contact holds the control circuit closed in normal operation. Pulling the rope opens it and stops the line. The NO contact closes at the same time for a signal or indicator.
- : 13-14 (NO), 21-22 (NC)
- : Type 1
- : IP67
- : EN50041, EN60947-5-1
- : M20 x 1.5
- : 1.5 kgf (14.71 N) at the metal pull ring
-
- : Industrial-grade flame-retardant shell
-
Material-handling elevator installations are where this model belongs, and manual reset is the reason. For material-handling elevators, the circuit must not re-close automatically: after the rope is pulled, the contacts stay open until a technician reaches the unit and presses the blue button. That is what an elevator has to do on any run where restart requires on-site personnel intervention. Industrial production lines and warehouse conveying come to this model for the same reason.
carry the CE, CCC, CB, CQ and RoHS marks, and the declaration of conformity for EN50041 and EN60947-5-1 is available on request. The plant covers 6,000 square meters in Ruijin City, Jiangxi Province, and our business office is located in Wenzhou, Zhejiang. OEM/ODM customization is supported. Share your project-required standards, and we will recommend the suitable for your application.
A: Yes. The CE, CCC, CB, CQ and RoHS certificates for this safety rope switch can be supplied on request, along with the declaration of conformity for EN50041 and EN60947-5-1. Send us the list your project needs and we will match it.
Q: What material is the pull-ring made of?
A: The pull-ring is a metal component built for reliable performance within industrial environments.
A: There is no fixed maximum rope length defined by the switch itself. However, please ensure the pulling force reaches the rated operating force of 1.5 kgf (14.71 N) when the rope is pulled. We recommend consulting us for your specific conveyor layout.